Coronavirus disease (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is rapidly spreading across the globe. The clinical spectrum of SARS-CoV-2 pneumonia requires early detection and monitoring, within a clinical environment for critical cases and remotely for mild cases, with a large spectrum of symptoms. The fear of contamination in clinical environments has led to a dramatic reduction in on-site referrals for routine care. There has also been a perceived need to continuously monitor non-severe COVID-19 patients, either from their quarantine site at home, or dedicated quarantine locations (e.g. hotels). In particular, facilitating contact tracing with proximity and location tracing apps was adopted in many countries very rapidly. Thus, the pandemic has driven incentives to innovate and enhance or create new routes for providing healthcare services at distance. In particular, this has created a dramatic impetus to find innovative ways to remotely and effectively monitor patient health status. In this paper, we present a review of remote health monitoring initiatives taken in 20 states during the time of the pandemic. We emphasize in the discussion particular aspects that are common ground for the reviewed states, in particular the future impact of the pandemic on remote health monitoring and consideration on data privacy.Visual prostheses are designed to restore partial functional vision in patients with total vision loss. Retinal visual prostheses provide limited capabilities as a result of low resolution, limited field of view and poor dynamic range. Understanding the influence of these parameters in the perception results can guide prostheses research and design.
In this work, we evaluate the influence of field of view with respect to spatial resolution in visual prostheses, measuring the accuracy and response time in a search and recognition task. Twenty-four normally sighted participants were asked to find and recognize usual objects, such as furniture and home appliance in indoor room scenes. For the experiment, we use a new simulated prosthetic vision system that allows simple and effective experimentation. Our system uses a virtual-reality environment based on panoramic scenes. The simulator employs a head-mounted display which allows users to feel immersed in the scene by perceiving the entire scene all around. Our experiments use public image datasets and a commercial head-mounted display. We have also released the virtual-reality software for replicating and extending the experimentation.
Results show that the accuracy and response time decrease when the field of view is increased. Furthermore, performance appears to be correlated with the angular resolution, but showing a diminishing return even with a resolution of less than 2.3 phosphenes per degree.
Our results seem to indicate that, for the design of retinal prostheses, it is better to concentrate the phosphenes in a small area, to maximize the angular resolution, even if that implies sacrificing field of view.
Our results seem to indicate that, for the design of retinal prostheses, it is better to concentrate the phosphenes in a small area, to maximize the angular resolution, even if that implies sacrificing field of view.Acquisition parameter selection is currently performed empirically for many quantitative MRI (qMRI) acquisitions. Tuning parameters for different scan times, tissues, and resolutions requires some amount of trial and error. There is an opportunity to quantitatively optimize these acquisition parameters in order to minimize variability of quantitative maps and post-processing techniques such as synthetic image generation. The objective of this work is to introduce and evaluate a quantitative method for selecting parameters that minimize image variability. An information theory framework was developed for this purpose and applied to a 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) signal model for qMRI. In this framework, mutual information is used to measure the information gained by a measurement as a function of acquisition parameters, quantifying the information content of potential acquisitions and allowing informed parameter selection. The information theory framework was tested on artificial data generated from a representative mathematical phantom, measurements acquired on a qMRI multiparametric imaging standard phantom, and in vivo measurements in a human brain. https://www.selleckchem.com/products/vtp50469.html The phantom measurements showed that higher mutual information calculated by the model correlated with smaller coefficient of variation in the reconstructed parametric maps, and in vivo measurements demonstrated that information-based calibration of acquisition parameters resulted in a decrease in parametric map variability consistent with model predictions.Iridium oxide films are commonly used as a high charge-injection electrode material in neural devices. Yet, few studies have performed in-depth assessments of material performance versus film thickness, especially for films grown on three-dimensional (instead of planar) metal surfaces in neutral pH electrolyte solutions. Further, few studies have investigated the driving voltage requirements for constant-current stimulation using activated iridium oxide (AIROF) electrodes, which will be a key constraint for future use in wirelessly powered neural devices.
In this study, iridium microwire probes were activated by repeated potential pulsing in room temperature phosphate buffered saline (pH 7.1-7.3). Electrochemical measurements were recorded in three different electrolyte conditions for probes with different geometric surface areas (GSAs) as the AIROF thickness was increased.
Maintaining an anodic potential bias during the inter-pulse interval was required for AIROF electrodes to deliver charge levels conF using model saline solutions.The momentum transport in ultraclean bilayer graphene is characterized by the viscous transport. In quantizing magnetic field the momentum current passes through the guiding center of the cyclotron orbit. In this study we derive the formula of the quantized Hall viscosity for bilayer graphene. This can be detected in the non-local magnetoresistivity measurements that varies with the quantized step. For weak magnetic field the Landau levels start overlapping and lead to the Shubnikov-de-Haas oscillations, superimposed on the classical formulae, Ref[1]. These oscillations are present in the longitudinal and Hall viscosities.